(C40)
(F6)
楼地面一体化磨石系统基于优砾科 FT40 高性能找平耐磨地坪砂浆,将传统水磨石楼地面的“找平层 + 面层”两层做法合并为一次浇筑的一体化层,并配套 EC26 水性环氧水泥界面剂与纳米陶瓷罩面,实现减薄、减重、高强、抗渗的装饰性耐磨楼地面。系统总厚度约 25 mm(不含结构层),相比传统现制水磨石(45~50 mm)大幅减薄。The Integrated Terrazzo Floor System is based on UNIKRETE® FT40 High-Performance Levelling and Wearing Floor Screed, combining the conventional two-layer “levelling + wearing” terrazzo construction into a single monolithic poured layer, together with EC26 Waterborne Epoxy Cement Primer and nano-ceramic topcoat, delivering a thinner, lighter, high-strength, impermeable decorative wearing floor. Total system thickness is approx. 25 mm (excluding the structural slab), substantially thinner than conventional cast-in-situ terrazzo (45–50 mm).
| 层次Layer | 材料/做法Material / Practice | 厚度/说明Thickness / Note |
|---|---|---|
| ① 基层Substrate | 钢筋混凝土楼板,清理、修补,必要时铣刨Reinforced concrete slab; cleaned, repaired and milled if required | 应坚固、无油污、无起砂Sound, free of oil and dusting |
| ② 界面层Interface layer | UNIKRETE® EC26 水性环氧水泥界面剂UNIKRETE® EC26 Waterborne Epoxy Cement Primer | 满涂,提高粘结,防止空鼓Full coating to enhance bond and prevent hollowing |
| ③ 一体化层Monolithic layer | UNIKRETE® FT40 高性能找平耐磨地坪砂浆,可配钢筋网片或钢丝网UNIKRETE® FT40 High-Performance Levelling and Wearing Floor Screed, with reinforcing or wire mesh if required | 目标厚度 25 mmTarget thickness 25 mm |
| ④ 表面处理Surface treatment | 养护 3 d 后研磨、抛光Grinding and polishing after 3 days of curing | 达到装饰性耐磨饰面Decorative wear-resistant finish |
| ⑤ 罩面层Topcoat layer | 纳米陶瓷膜 / 纳米陶瓷罩面Nano-ceramic membrane / nano-ceramic topcoat | 疏水疏油、防尘自洁Water & oil repellent, dust-proof and self-cleaning |
一体化楼地面构造:系统总厚度约 25 mm(不含结构层)。Integrated floor build-up: total system thickness approx. 25 mm (excluding the structural slab).